Tag Archives: Palm Springs deck inspector

Does Your HOAs Reserve Study Include All the Costs/Work Involved to Replace a Balcony at the End of Its Useable Life?

I’ve spoken with numerous reserve study folks about balconies/decks/walkways and the scope of work that replacing a balcony requires.

You can read our article about installing deck waterproofing systems at our articles page here

I’m not sure all of them understand that a waterproof deck replacement project is far more than just replacing the waterproofing system. Known as pedestrian traffic coatings, walking deck systems are composed of several different things, including flashings at the deck to wall and at any outside edges. Deck drains or scuppers may be involved. Door pans for the sliding or French door are also something that needs to be addressed.

In order for our readers to better understand, I’m going to break down the work a deck replacement involves.

So let’s say your exclusive use common area balconies are 25-30 years old, have been reasonably maintained but are now starting to require a lot of repairs. Your reserve study says the decks need to be replaced at year 25-30. Like any building component, deck waterproofing systems do wear out and need to be replaced.

A typical detail that must be followed when installing new flashings and waterproofing.

Let’s break down what a full deck replacement really looks like and my reserve study peeps can go back and see if their projected costs include the following basic scope of work. If you’re a Board member or HOA manager, you’ll want to ask your reserve study provider if they are taking all the work necessary into account for estimated costs of replacement.

So to start with, the deck waterproof coatings needs to be removed. This will also include removing and installing new plywood substrate. Always replace the existing substrate with plywood as it required by every  traffic coating manufacturer. The  contractor will need to  open the walls in order to remove the deck to wall flashings as well as removing the sliding door to access the rough opening and the door flashing/door pan under the sliding door. Breaking open stucco or removing other wall finishes to remove and reinstall flashings requires restoration of the wall after the deck is replaced. Replacing a three coat stucco wall is one thing, but replacing other wall finishes such as EIFS or Hardi Board will incur further expenses.  Older siding such as Masonite, an inexpensive siding that’s no longer manufactured, may require even more work to replace it with new current siding systems.

There’s an art to installing pedestrian traffic coatings.

After stripping down the deck to the joists, some joists may be damaged and bed reports or replacement. Those unknown costs should have a line item in the reserve study under a unknown costs category. Maybe ask the hosts will be ok, maybe they won’t. It’s better to budget for some repairs.

The sliding door or French door needs to be removed to install a door pan. (Doors are usually an owner responsibility to maintain, repair and eventually replace.).  This is a good time for old doors to be replaced with modern doors that have glass that reduces UV and heat coming through and are generally better at functioning and resisting rain and wind. Rarely will a contractor remove doors without first informing the HOA that doors may be damaged and that they aren’t responsible for any damages to the doors. If the doors are 25+ years old, owners should buy new doors.

Typical balcony flashing system detail.

The deck, if it doesn’t already, needs to be sloped to drain, either to an open edge or to a deck drain or scuppers.

New flashings at the deck to wall need to be replaced with new flashings, integrated into the door pan. If there are scuppers on the outside wall, they need to be integrated with the deck to wall flashings.

Always replace deck drains that go through the floor of the deck during the deck replacement. Modern deck drains are using brass plumbing pipe and stainless steel flanges welded to the pipe.

A high quality deck waterproofing system is recommended. Cheap deck waterproofing systems have a shorter useable life span and generally require a lot more maintenance.

One issue that may arise during a deck replacement project is that you’ll probably need a building permit. New codes may take precedence. Right now code generally requires railings to be 42″ high and have openings  4″ apart or less. If your current railings don’t meet that standard, that’s a cost that doesn’t show up in a reserve study. So you need to have a contingency for increased costs necessary to meet building codes of the future.

Once your new deck system is installed and the walls are closed up and you turn the decks back to the resident, you now start the clock ticking on the maintenance cycle that the EEEs require. Many pedestrian traffic coating systems require resealing/painting the decks every 3-5 years. If you fail to do so and there’s a problem down the road, a warranty claim may be denied. Besides keeping the deck looking nice, a clean and reseal gives the association the ability to inspect thru deck and make any minor repairs before they become big repairs.

So your reserve study needs to have a line in it for deck maintenance. Your deck contractor can give you a schedule for resealing. Trust me when I say I recommend you follow the maintenance schedule. If you do you’ll maximize the expected life span of the waterproofing. Because of the costs to replace a deck earlier than it’s expected life span, you want to do this.

Your reserve study also needs a line item in it for reserving for the replacement costs of the deck again 25-30 years down the road.

Follow our advice and your association  may realize lower costs in the future. If you fail to inspect ,maintain and repair,you can expect a shorter usable life span, and large costs to replace the deck before its time.

Does your association need help in determining costs, inspecting your decks for maintenance requirements or to get a grasp on what condition your EEEs are in to dial in your decks estimated life spans for your reserve study, reach out today. We can help your HOA take control of your EEEs rather than letting your EEEs control you.

The Balcony Inspection Transparency Project is Coming!

We document. We disclose. You decide.

Is the HOA industry ready to demand transparency? We are!


Introducing the Balcony Inspection Transparency Project

http://www.balconytransparency.org (coming soon)


William Leys Waterproofing Consultants LLC is a founding member—and we are inviting other California inspection companies to participate.


California homeowners associations, apartment owners, community managers, and building owners are being asked to make important decisions about balcony and exterior elevated element inspections. Those decisions can affect occupant safety, association finances, reserve planning, repair priorities, and long-term property maintenance.


Consumers deserve to know exactly who they are hiring.


That is why William Leys Waterproofing Consultants LLC is a founding member of the Balcony Inspection Transparency Project, or BITP.


BITP is being developed as a source-based consumer-information project focused on companies offering balcony, deck, and exterior elevated element inspection services in California. Its purpose is straightforward: make important information about inspection providers easier to find, understand, compare, and correct.

I don’t want to do this just on my own, so if you would like to volunteer as a participant to ensure a fair and even process across the board, feel free to let me know!


We document. We disclose. You decide.


We Are Seeking Cooperation Across the Industry
BITP should not be a directory in which one company gets to ask questions of everyone else while avoiding those same questions itself.
William Leys Waterproofing Consultants LLC intends to complete the same transparency questionnaire offered to every participating company. We will identify our company’s ownership, services, professional relationships, role in SB 326 projects, relevant licenses and qualifications, business affiliations, and whether we or another participant may have a financial interest in related services.


We are inviting balcony inspection companies, engineering firms, architectural firms, contractors, consultants, and other businesses offering exterior elevated element inspection services to participate voluntarily and without charge.


Participating companies will have an opportunity to:
Describe their company and inspection process in their own words;


Identify who performs field inspections;


Explain who prepares, reviews, signs, or seals the final report;


List applicable California professional and contractor licenses;


Explain certifications and professional designations they advertise;


Disclose relationships with credentialing organizations, training companies, associations, engineering firms, contractors, and repair providers;


Describe insurance and conflict-of-interest practices;


Provide supporting records and links; and
Correct, clarify, or update information appearing in their profile.


Download the Fillable BITP Company Questionnaire


Submit a Company Profile Online


What Consumers Should Be Able to Learn


A company profile should answer more than, “Does this business advertise balcony inspections?”


Consumers should be able to determine:


Who is actually performing the fieldwork?


Who exercises the professional judgment required by the applicable law?


Who is responsible for the final report?


What California licenses do those people hold?


Is an advertised certification governmental, private, association-issued, manufacturer-issued, or simply evidence of completing a training course?


Who created and controls the organization issuing that certification?


Does the inspection company—or a related business—perform repairs arising from its findings?


Are referral fees, commissions, reciprocal referrals, or other financial relationships involved?


Are important advertising claims supported by current, identifiable sources?


These questions do not assume that a particular business arrangement is improper. Inspection companies can be structured in many legitimate ways. Engineers, architects, contractors, consultants, technicians, and specialty firms can each have appropriate roles depending on the property, applicable statute, agreement, supervision, and scope of services.


The important point is that the consumer should not have to guess what those roles and relationships are.


Participation Is Not Certification or Endorsement


BITP will not call participating companies “BITP Certified.” Participation will not mean that BITP has approved, recommended, ranked, accredited, or guaranteed a company’s work.


A participating company will be identified as having supplied standardized information. Individual fields may be labeled:


Company supplied;


Company representation;


Corroborated by identified source;


Not independently reviewed;


Not disclosed; or


Disputed information.


Profiles may be published after private administrative review even when every factual field has not yet been independently corroborated. Unreviewed information will be labeled accordingly. That distinction allows companies to participate promptly without causing consumers to mistake company-supplied information for government verification or BITP endorsement.


What If a Company Does Not Participate?


Participation is voluntary. A company’s decision not to complete the questionnaire does not prove that the company has done anything wrong.
BITP may nevertheless create a Public-Information Profile using identified sources such as government licensing databases, Secretary of State records, company websites, archived webpages, published advertising, organizational records, and other material that can reasonably be authenticated.


Those profiles will be conspicuously labeled:


Public-Information Profile


This profile was compiled from the identified public sources. No completed, authorized company questionnaire has been incorporated as of the date shown.


Companies will be encouraged to respond, submit corrections, provide additional context, or complete the full questionnaire.


Why Hesitation Deserves Closer Attention


Balcony and exterior elevated element inspections can involve life-safety concerns and significant financial consequences. A credible provider should be prepared to answer reasonable questions about identity, qualifications, responsibility, and financial relationships.


If a company is hesitant or unwilling to identify who performs the inspection, who signs the report, what license the responsible professional holds, who issues an advertised certification, or whether affiliated businesses may profit from resulting work, a prospective client should pause and investigate further before signing a contract.


That hesitation is not proof of illegality, incompetence, dishonesty, or an improper conflict. There may be a reasonable explanation. But unanswered questions involving professional responsibility and financial interests are relevant warning signs. Consumers should request written clarification, verify public records, compare other providers, and decide whether they are comfortable proceeding.


Transparency does not require every company to use the same business model. It requires the company to describe its model accurately.


Why We Believe Transparency Improves the Industry


Clear disclosure rewards companies that are willing to identify the people performing the work, explain credentials accurately, disclose affiliations, and distinguish inspection services from repair opportunities.


It also helps consumers compare proposals on something more meaningful than price alone.
An HOA board should be able to compare:


The actual inspection scope;


The qualifications and role of each participant;


The applicable sampling approach;


The person responsible for professional findings;


The report and follow-up services included;


Potential additional charges;


Credential and association relationships; and
Any financial interest in subsequent testing, design, construction, or repair work.


When those facts are clear, responsible providers compete based on documented qualifications, defined scope, professional accountability, and the value they provide.


BITP Will Accept Corrections, Responses, and Consumer Evidence


The Project is also being designed to accept documented corrections, company responses, and private consumer-experience submissions.
Consumer submissions will not appear automatically as anonymous reviews or star ratings. BITP may privately verify the submitter, examine supporting documents, redact personal information, seek a company response, and distinguish between firsthand experience, company statements, public records, and BITP analysis.


The goal is not to create a complaint wall. The goal is to build a useful, fair, and correctable information resource.


Our Own Interest Will Be Disclosed


BITP is founded and published by William Leys and William Leys Waterproofing Consultants LLC. WLWC operates in the waterproofing consulting and balcony inspection-related industry. We therefore have a commercial and professional interest in the subject matter.


We will disclose that interest rather than describe BITP as an independent review website. When BITP discusses a person or company with whom the publisher has had a material business, regulatory, legal, or competitive relationship, that relationship should be specifically disclosed on the relevant page.


The credibility of the Project must come from consistent questions, identified sources, fair attribution, meaningful responses, visible corrections, and standards applied to WLWC as well as everyone else.


An Open Invitation to California Inspection Providers


If your company provides SB 326, SB 721, balcony, deck, waterproofing, or exterior elevated element inspection services in California, we invite you to become part of the Balcony Inspection Transparency Project.
Participation is free.


Tell consumers who you are. Identify the people responsible for your work. Explain your credentials. Disclose relevant affiliations. Provide sources that allow important information to be checked. If something in a profile is incomplete or wrong, help us correct it.
We are not asking other companies to disclose information that we are unwilling to disclose ourselves.


Download the Fillable Questionnaire (Coming soon)


Learn More About the Balcony Inspection Transparency Project


Publisher disclosure: The Balcony Inspection Transparency Project is founded and published by William Leys and William Leys Waterproofing Consultants LLC, which provides waterproofing consulting and balcony inspection-related services in California. Participation in BITP does not constitute certification, approval, ranking, recommendation, or endorsement.


William Leys Waterproofing Consultants LLC
805-801-2380
wleyswaterproofingconsultants.com

Transparency Matters: How We’ve Clarified Our SB 326 Inspection Process

Our Updated Logo Reflects Our Role Coordinating SB 326 Inspections

At William Leys Waterproofing Consultants LLC, we believe that an HOA board should understand exactly who it is hiring, what services each professional will provide, and who is responsible for the engineering judgments required as part of an SB 326 inspection.

Recently, correspondence from the California Board for Professional Engineers, Land Surveyors, and Geologists (BPELSG) gave us an opportunity to take a closer look at how we described our SB 326 services on our website and in our proposals.

We took that opportunity seriously.

The result is a clearer and more transparent description of our role, the role of the licensed structural engineering firm performing the engineering services, and how the different parts of an SB 326 project are coordinated for our clients.

Why We Made Changes



SB 326 projects can involve several different disciplines.

There is an important distinction between waterproofing and building-envelope consulting, project coordination, and the professional engineering services that California law reserves for appropriately licensed professionals.

Although we understood those distinctions in practice, the Board’s correspondence caused us to examine whether they were communicated clearly enough in our marketing and contractual documents.

We concluded that we could do better.

Rather than simply changing a few words, we reviewed our website and proposal language with the goal of making the relationship easier for an HOA board, community manager, or building owner to understand before retaining us.

Clearly Identifying Who Performs the Engineering Work

One of the most important changes is greater clarity about the licensed engineering firm’s role.

William Leys Waterproofing Consultants LLC is a waterproofing consulting and project-coordination company. We do not represent ourselves as a licensed engineering firm.

When professional engineering services are required for an SB 326 project, those services are performed by the licensed engineering firm identified for the project.

That distinction is now stated more clearly in our materials.

The engineer is responsible for the engineering observations, professional opinions, determinations, and engineering report within the engineer’s scope of services. The engineering report is prepared and signed or sealed as required by the licensed professional responsible for that work.

Our role is separately described so clients can understand the services William Leys Waterproofing Consultants provides.

What William Leys Waterproofing Consultants Brings to the Project

Our expertise is rooted in waterproofing.

We have been inspecting decks and evaluating waterproofing conditions since 2007. That field experience gives us a practical understanding of how exterior elevated elements are constructed, how waterproofing systems deteriorate, where water commonly enters assemblies, and how seemingly minor waterproofing defects can contribute to much larger problems.

On an SB 326 project, our work may include project coordination, documentation, communication with the client and engineering firm, waterproofing-related observations and consulting, and coordination of other services within our agreed scope.

But experience with waterproofing does not turn a waterproofing consultant into an engineer.

We believe clients deserve to understand that distinction.

Transparency Should Start Before the Contract Is Signed

An HOA board should not have to decipher a website or proposal to figure out who will actually perform the professional services being offered.

Our revised approach is intended to answer those questions upfront.

Before retaining us, a prospective client should be able to understand:

– who the client is contracting with;
– what William Leys Waterproofing Consultants LLC is responsible for;
– which services will be performed by a licensed engineering firm;
– who is responsible for professional engineering judgments and the engineering report;
– what services are included in the proposed scope; and
– what additional investigation or services may be recommended if conditions discovered during the project warrant them.

We believe this level of clarity is good for everyone involved.

Taking Regulatory Guidance Seriously

Businesses sometimes view questions from a regulatory agency as something to fight or minimize.

We chose a different approach.

The Board’s correspondence gave us a reason to review how we communicated our services and ask a straightforward question:

Could an HOA board reading our website or proposal misunderstand who is performing the engineering services?

Where we believed the answer could possibly be yes, we changed the language.

That process has resulted in materials that we believe more accurately describe the respective roles of William Leys Waterproofing Consultants and the licensed engineering professionals involved in an SB 326 project.

Experience and Professional Licensure Are Different Things

California’s SB 326 inspection requirements exist for an important reason: exterior elevated elements can present serious safety concerns when deterioration is allowed to progress unnoticed.

A successful inspection program therefore benefits from both professional engineering judgment and practical knowledge of waterproofing systems and the conditions that cause them to fail.

Those are complementary areas of expertise, but they are not interchangeable.

Our goal is not to blur that distinction. It is to make it clear.

A Better Process for Our Clients

We believe the changes prompted by the Board’s correspondence have made our company better.

Our website is clearer. Our proposals are clearer. The responsibilities of the participants are better defined. And prospective clients receive more information about the structure of the engagement before deciding whether to hire us.

For an HOA board making decisions involving building safety, association funds, and long-term maintenance obligations, transparency shouldn’t be an afterthought.

It should be part of the inspection process from the beginning.

—

Questions About an SB 326 Project?

William Leys Waterproofing Consultants LLC provides waterproofing consulting and SB 326 project-coordination services for homeowners associations and building owners throughout California.

If your association is preparing for an SB 326 inspection or trying to understand the condition of its exterior elevated elements and waterproofing systems, contact us to discuss the project, our scope of services, and the role of the licensed engineering professionals involved.

Continue reading Transparency Matters: How We’ve Clarified Our SB 326 Inspection Process →

Balcony Collapse in Hawaii Injures Seven People!

We’re still trying to get more information, a balcony collapsed in Hawaii with 7 people on it. The balcony appears to have only been nailed to the building from what we can see.

As seen here, the deck appears to have fallen off the building. It appears to have been nailed into the building instead of bolted. An inspection probably would have caught that flaw.
Photo used under the fair use doctrine for education.

This is why inspections matter! The 11th anniversary of Berkeley was two days ago, and here we are again, another collapse. For the people on this balcony, they were injured but they will all be going home from reports I’ve read.

Please schedule your inspection ASAP, if you are renting property either through Airbnb or long-term, protect yourself and your tenants with an inspection.

We serve San Luis Obispo County as well as Santa Barbara and Ventura County for deck inspections under SB326 and general inspections for rental and personal property.

Call today 805-801-2380

HOAs Are Required to Have Final Inspection Reports Issued After Repairs are Done Under SB-410


Attention HOAs, SB 410 took effect on January 1st and imposes certain requirements on HOAs and on balcony inspection companies.

For HOA Boards of Directors, you are affected in several ways; the first being that SB326 reports are now considered to be HOA records, which means an owner can request and review them at any time. Secondly, reports cannot be withheld or redacted and third sellers of a common interest development property now must provide buyers with the most recent SB326 inspection report.


In regards to inspection companies, their reports must include as of January 1st, the date of the inspection, the total number of units in the community. How many exterior elevated elements there are? And I think it would be a good idea to break down how many of each type there are IE stairs versus balcones versus walkways. How many units have exterior elevated elements? How many exterior elevated elements were inspected and whether any safety concerns were identified.

The independent engineer we work with is already in compliance with these requirements and so we are ready to forge ahead and set the bar with our superior inspections and inspection reports.

Lastly But probably the most important part of sb410 is the requirement for HOAs to have an engineer issue a final report after repairs are made to life safety issues. This final report is needed to be able to enable buyers of property obtain mortgages and sellers of properties to be able to sell without undue delay. Personally, I expect that we will see legal claims brought against HOAs that fail to obtain final inspection reports and unnecessarily delay there homeowners to be able to close a sale.

As always, this is not legal advice. Please obtain the advice of your HOA attorney related to SB 410 sb326 and any other bills that may affect common interest developments related to balcony inspections.

If your HOA is having problems with condos being sold because of the lack of a final report, call us today, we can do a final inspection report regardless of whether we inspected the EEEs originally or another company did. Call 805-801-2380 today!

Watch Our Videos on TikTok, Insta & YouTube!

Did you know that we have a YouTube, Instagram and TikTok channel for you to keep up with us? Yep it’s true.

We post our latest videos first on TikTok. Follow us here  http://tiktok.com/@bill_leys_the_deckexpert

Then we generally post to YouTube a few days later. Follow us here https://youtube.com/@bill-leys-is-the-deck-expert?si=CkGOi5RC7ps4w_Z0

Soon after we post the videos to Instagram, follow us here https://www.instagram.com/wleyswaterproofingconsultants?igsh=MzRlODBiNWFlZA==

We appreciate the outreach from so many people around the state who are appreciative of what we’re doing here at William Leys Waterproofing Consultants LLC!

If you don’t trust your balcony inspection report, if your balcony inspection company is pressuring you to take out special assessments, if your balcony inspection company also does repairs, you need to reach out to us today to help you defend against unethical immoral tactics designed to separate your HOA from its money. We perform second opinion inspections that can help an HOA determining if they got a good report or not.

Call today, I answer the phone personally! Bill Leys 805-801-2380

Personal service at affordable prices!

Instagram Featured Video Stair Rebuild by One Structural/Balcony 1 Shows Multiple Construction Defects Being Installed in Real Time!

“Clowns to the left of me, jokers to the right, here I am, stuck in the middle…”

A recent Insta video posted by One Structural/Balcony 1 reminded me of the lyrics from a 1972 song by Stealers Wheel… And after watching the video several times I wondered why I wasn’t having a stroke over the numerous defects in their work. The video purports to show their expertise in rebuilding a set of stairs and waterproofing them. (The video appears to have been removed from their profile located here https://www.instagram.com/onestructural?igsh=MzRlODBiNWFlZA==)

In the video it showed a timeline of rebuilding a set of stairs. As I watched it play out I screenshot a few pics, see below.

Starting with the framing rebuild, we can see water/fungus damaged stair stringers that weren’t replaced, damaged sheathing on the wall that wasn’t replaced and new wood that looks like my 3 year old nephew installed.
Continue reading Instagram Featured Video Stair Rebuild by One Structural/Balcony 1 Shows Multiple Construction Defects Being Installed in Real Time! →

Is Dr Balcony Competent to Discover Defects? We Have Doubts After Our Re-Inspection of EEEs Found Multiple Defects They Failed to Identify!

We were recently hired to do a follow-up inspection at a condo in the Los Angeles area. The client, an individual homeowner, had serious concerns about the report the association received from Dr Balcony. Their concerns began when the inspection was done, saying that a person showed up, said they weren’t licensed but that “someone” who was a licensed architect would review their photographs and information before signing the report.

We got a copy of the Dr Balcony report and reviewed it before we did our own inspection. (Please note our inspection was not an SB326 inspection.) Many of the photographs in the report were blurry and weren’t marked up to identify a defect that supposedly was in the photograph (we mark up all our photographs to show you exactly what defect we found) and the report was difficult to read. We completely agree with our client, I’ve read more than a few reports from other companies and Dr Balcony’s report is a tough read. Defect codes that are for their internal use confuse readers, information on an EEE are in different places and many photographs are of irrelevant subjects.

An example of that is Dr Balcony inspectors seem to obsess over code issues that SB 326 doesn’t require us to concern ourselves with. (We do check railing heights & railing stiles and note that they may not meet current code, same with stairs, but these aren’t noted as defects, rather we advise that the HOA may wish to address these in the future and that your insurance company may require upgrading in order to renew a policy).

Continue reading Is Dr Balcony Competent to Discover Defects? We Have Doubts After Our Re-Inspection of EEEs Found Multiple Defects They Failed to Identify! →

SB-410 Takes Affect January 1st 2026, Is Your Inspector Compliant With Its Requirements? We Are!

January 1st is almost upon us and every year in California we see new laws come into effect on the first of the year and this year is no different.

You can watch our video here if you prefer

Deck Expert Bill Leys Discusses SB 410 & How It Effects HOAs & Deck Inspection Firms Reports

Notably for HOAs and balcony inspection companies SB 410 will take effect on January 1st and impose certain requirements on HOAs and on balcony inspection companies.

For HOA Boards of Directors, you are affected in several ways; the first being that SB326 reports are now considered to be HOA records, which means an owner can request and review them at any time. Secondly, reports cannot be withheld or redacted and third sellers of a common interest development property now must provide buyers with the most recent SB326 inspection report.

Continue reading SB-410 Takes Affect January 1st 2026, Is Your Inspector Compliant With Its Requirements? We Are! →

Santa Monica Condo Board Selects William Leys Waterproofing Consultants LLC to Coordinate Their SB 326 Inspection

We’re pleased to announce that we were awarded the contract to coordinate a SB 326 inspection for a condominium complex on Pacific Street in Santa Monica. The three story building with decks stairs and walkways requiring inspection received several bids from competitors.

The Board after reviewing the bids and each firms credentials, selected our bid over the others, citing that our bid included a guarantee that a licensed independent structural engineer will personally inspect the EEEs, that we don’t perform repairs and that our inspection team’s bonafides gave them the confidence in awarding the job to William Leys Waterproofing Consultants LLC.

These walkways and stairs are EEEs as defined in SB 326 and will be inspected by the best inspection team in the industry.

Of course it might also have helped that the Associations Board has an engineer serving as president and recognized that qualifications matter. Our independent structural engineer is an award winning engineer with years of experience doing structural inspections.

Continue reading Santa Monica Condo Board Selects William Leys Waterproofing Consultants LLC to Coordinate Their SB 326 Inspection →

Signal Hill Condo Selects William Leys Waterproofing Consultants LLC To Coordinate Their SB 326 Inspection

  • Board Treasurer Says Our Detailed Proposal Stood Heads Above Competing Firms
  • Our Expertise & Guarantee That An Independent Structural Engineer Performs the Inspection Stands Out Over Other Firms

We’re happy to announce that we were selected to coordinate balcony inspections at a mid rise HOA in Signal Hill by the Board of Directors. Our detailed proposal and years of experience gave the Board of Directors the confidence that we were the best choice out of the five firms bidding.

Cantilevered Balcony at A Signal Hill Condo Association

We are so happy to hear strong praise like this as it reinforces our belief that we are one of the best qualified firms in the balcony inspection industry.  Our guarantee of no conflicts of interest, our guarantee that an independent structural engineer personally performs the inspection and that our 20+ years of prior experience in waterproofing as deck contractors is a deciding factor, along with competitive rates for Boards faced with enormous pressure to get in compliance with SB326’s requirements to inspect.

Let us show you why we are one of the best firms coordinating SB 326 inspections in the industry and let us earn your business with our professionalism and expertise. Get in touch today by calling 805-801-2380 and talk to Bill Leys with no obligation whatsoever.

Our best clients are educated clients!

High Compliments From an HOA Client

It is always nice to get unsolicited compliments from our clients and the one that we received yesterday from Joseph in Los Angeles is very appreciated.

We try very hard to bring the best in service and stay on top of current trends in the industry to make sure our clients get the very best advice that we can give.

If your HOA needs help in coordinating SB 326 balcony inspections with licensed independent structural engineers, roof consulting or building envelope water intrusion issues, let me help you. Reach out today for a free discussion on what William Leys Waterproofing Consultants LLC can bring to the table in value for your community.

From an HOA client in Los Angeles, we sincerely appreciate the compliments!

In Somber Remembrance of The Tenth Anniversary of the Berkeley Balcony Tragedy

A chilling tragedy at Library Gardens in Berkeley occurred ten years ago today, June 16th, 2015 when a deck collapsed with thirteen people on it, killing seven people and leaving six people permanently injured. This is why we inspect.

Take a moment to remember the victims of Berkeley who lost their lives that terrible night on June 16th 2015 – Ashley Donohoe, Olivia Burke, Eoghan Culligan, Niccolai “Nick” Schuster, Lorcán Miller, Eimear Walsh and Aoife Beary and the survivors, who remain permanently injured, Clodagh Cogley, Seán Fahey, Conor Flynn, Jack Halpin, Niall Murray and Hannah Waters.

This should never have happened, yet it did. Poor construction practices and in my opinion outright negligence caused this accident..

In somber remembrance of the victims of the Berkeley balcony tragedy, we want to remind everyone that this is accident is why we inspect. This can never happen again, this is why SB326 and SB721 are now in effect. As professional inspectors, we take our duty to save lives and property very seriously.

Please get your decks inspected, the life you save could be your own.

Check Out Our YouTube Videos Here

We just wanted to send you to our articles and videos page to check out the videos from our YouTube channel!

http://sb326deckinspectors.com/articles-powerpoint-presentations-by-bill-leys/

Here are a couple of our most popular vids. Leave a comment and subscribe to our channel!

Learn about how deck drains and scuppers should be installed and why it’s important to counter flash scuppers on the exterior walls.
Learn about ember resistant vents for balconies. Soffits + crawl spaces
Here we discuss who can perform inspections and who must write and sign the report for sb326.
Poor workmanship doomed this new addition with intrusion, resulting in tens of thousands of dollars worth of damage to restore the waterproofing. 

Protect Your HOA, Insist That any Company Bidding Your SB326 Inspection Signs This Certification Guarantee

If you have been following our blog for any time now you know that we have been railing against the practice that is roiling the inspection industry where unethical inspection companies are using Engineers or Architects to robo sign reports that they have written after they have done the inspection. Sb326 clearly requires a licensed architect or engineer to perform the inspection however some companies are trying to deliberately circumvent that requirement and are using contracted labor to do the inspection instead of an architect or engineer.

We made up this form that you should ask your inspection company to fill out and certify/attest that their inspections follow the letter of the law and that a architect or engineer shall be performing the inspection.

Continue reading Protect Your HOA, Insist That any Company Bidding Your SB326 Inspection Signs This Certification Guarantee →